+86 769 2316 4266
Walk in Temperature Humidity Climatic Stability Test Chamber is used to test various types of materials for their tolerances of heat, cold, dry, humidity. It is applied for quality inspection for All types of big test samples, such as electronic products, electric appliance, and products from communication, instrument, automobile, plastic, metal, food, chemical,
Building materials, medical and aerospace industries.
We provide two primary types of walk-in chamber designs:
1.Modular walk-in chambers utilize foam panels that are connected together to form various size rooms.
2.Welded (Solid) walk-In chambers are fully welded chambers that can withstand high temperature and high humidity along with fast temperature change rates.
5% R.H low humdity walk in temperature humidity test chamber room
• Protection (phase protection, overheat, over current etc)
• Water Tank with level detector
• Adjustable Shelf
• With RS485/232 output to computer
• Window Software
• Remote fault notification(optional)
• With Viewing Window
Application:
Temperature Humidity Controlled Stability Chambers is used to test various types of materials for their tolerances Of heat, cold, dry, humidity. It is applied for quality inspection for all Types of big test samples,Such as electronic products, electric appliance, and products from communication, instrument,Automobile, plastic, metal, food, chemical, building materials, medical and aerospace Industries.
Technical Parameters | |
Model | THR-volume (low-temperature options : A ~ F) |
Inner Dimensions(cm) | Customers designated space size and design |
Temperature Range | Low Temperature(A:25degree C B:0degree C C:-20degree C D:-40degree C E:-60degree C F:-70degree C ) High Temperature 80 degree C (80degree C ~150degree C is optional) |
Humidity Range | 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need dehumidifier) |
Indication Resolution/ Distribution Uniformity of Temperature & Humidity | 0.1degree C ; 0.1% R.H/±2.5degree C ; ±3.5% R.H. |
Control Accuracy of Temperature and Humidity | ±0.5degree C ; ±2.5% R.H. |
Temperature Rising/ Falling Velocity | Temperature rising approx. 0.1~3.0°C/min; temperature falling approx. 0.3~1.0°C/min; ( The Falling Velocity Min.1.0°C /min is a optional) |
Cooling System | Water cooled |
Protection Devices | Fuse-free switch, overloading protection switch for compressor,high and low voltage coolant protection switch, over-humidity & over-temperature protection switch, fuses, fault warning system, water short storage warning protection |
Optional Accessories | Slope for cart , Recorder, Water Purifier, Dehumidifier |
Compressor | French Tecumseh Brand, Germany Bizer Brand |
Power | AC 380 V(±10%),50/60HZ ,3 phase 5 Lines |
Characteristics
1.New design temperature humidity climate test chamber walk in test chamber Evaporator no frosting under longtime Low temperature and low humidity running.
2.Automatic control system refrigerant demand save electricity above 30%
3.High heat load tested samples test environment
4.realize 95°C 95%high temperature and high humidity environment.
5.10% 20 °C ultra-low temperature range control ability
6.Multi-language selection: Chinese, English, Russian, Korean, Japanese, German multilingual language switching.