1500l Double-open Swing Door High & Low Temperature And Low Humidity Test Chamber

1500l Double-open Swing Door High & Low Temperature And Low Humidity Test Chamber

Design for temperature & humidity tests, cold resistance tests, thermal cycle tests, ultra low-temperature tests, high-temperature tests, storage conditions, and calibration functions.

We Supply a large range of standard and custom temperature and humidity test chambers to suit many types of environmental test conditions.  

This Chamber With two door open allows for a bigger item. With open width 1500mm, Height 1000mm and Depth1000mm


Our advise for choosing a suitabel chamber size is to mention always the Max size of the test subject in L, W, H with our sales team.

No worry with original factory.  ASLI will have a best solution for you. 





Inquire Now
Description

1500l Double-open Swing Door High & Low Temperature And Low Humidity Test Chamber


Name a test standard you are demanding the equipment for testing

IEC61215

GB9535

IEC61646

GB18911

UL1703

IEC62108

etc....


Technical Parameters


ModelTH-1500

Internal Dimensions WxHxD (mm)1500X1000X1000
External Dimensions WxHxD (mm)2150X2100X1750
Temperature Range 

Temperaure Min : -80°C ;  -70°C;  -60°C;  -40°C;  0°C ; Room Temperature

Temperature Max: +80°C ;  +100°C ; +150°C ;  180°C ;  200°C;



Humidity Range20%~98%R.H.
Indication Resolution/0.1°C; 0.1% R.H / ±2.0°C; ±3.0% R.H.
Distribution
Uniformity of
Temperature
and Humidity
Control Accuracy±0.5°C; ±2.5% R.H.
of Temperature
and Humidity
Temperature Rising/ Falling VelocityTemperature rising approx.  0.1~3.0°C/min;
temperature falling approx.  0.1~1.5°C/min;
Interior and Exterior MaterialInterior material is SUS 304# stainless steel,exterior is stainless steel or  SEE cold-rolled steel with paint coated.
Insulation MaterialResistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials
Cooling SystemWind cooling
Protection DevicesFuse-free switch, overloading protection switch  for compressor, high and low voltage coolant protection switch, over-humidity and over-temperature protection switch, fuses, fault warning system, water short storage warning protection
Optional AccessoriesInner door with operation hole(Optional), Recorder(optional),Water Purifier
CompressorFrench Tecumseh Brand, Germany Bizer Brand




1500l Double-open Swing Door High

1500l Double-open Swing Door High